Search In this Thesis
   Search In this Thesis  
العنوان
Effect of two different sizes ball and socket attachments retaining mandibular overdenture on mandibular bone :
المؤلف
Youssef, Sherif Ahmed.
هيئة الاعداد
باحث / شريف أحمد يوسف
مشرف / صلاح عبدالفتاح حجازى
مشرف / أحمد سمير خيرالله
الموضوع
Implant-supported dentures. Complete dentures. Prosthodontics. Denture, Overlay. Maxilla. Mandible.
تاريخ النشر
2017.
عدد الصفحات
133 p. :
اللغة
الإنجليزية
الدرجة
ماجستير
التخصص
Periodontics
تاريخ الإجازة
01/03/2018
مكان الإجازة
جامعة المنصورة - كلية طب الأسنان - Removable Prosthodontics
الفهرس
Only 14 pages are availabe for public view

from 133

from 133

Abstract

Statement of problem: The effect of different diameters of ball and socket retained mandibular complete overdenture on mandibular bone resorption has insufficient data. Purpose: This study aimed to evaluatethe marginal bone height changes and the posterior ridge area index of a mandibular overdenture retained by two different sizes of ball and socket attachments. Materials and methods:Six male patients with reduced stability and insufficient retention of mandibular dentures received 2 implants in the interforminal region. Implants were connected to mandibular overdentures with ball and socket attachments. According to the ball diameter, the patients were classified into two groups: group I received 2.5mm ball diameter and group II received 1.8mm ball diameter. Marginal bone height changes and posterior ridge area index were evaluated 6 months after overdenture insertion (T1), 12 months (T2) and 18 months (T3). Results: Marginal bone resorption was measured through the evaluation period in both groups. group I showed (0.79), (1.3) and (1.7) values regarding the vertical marginal bone loss respectively and showed (0.45), (0.69) and (0.98) values regarding the horizontal marginal bone loss respectively. group II showed (0.41), (0.67) and (1.1) values regarding the vertical marginal bone loss respectively and showed (0.17), (0.27) and (0.39) values regarding the horizontal marginal bone loss respectively. Regarding the posterior area index, group I recorded (1.6), (1.7) and (1.8) values respectively. group II recorded (1.6), (1.7) and (1.8) values respectively through the evaluation period (6, 12 and 18 months). There was statistically insignificant difference between the two groups regarding the posterior area index at all observation times. Conclusion: Ball and socket retained mandibular overdentures with a 1.8mm ball diameter were associated with less vertical and horizontal bone resorption compared with 2.5 mm ball diameter after a follow up of 1.5 years.