Search In this Thesis
   Search In this Thesis  
العنوان
Comparsion between all zicronia, all peek and zirconia-peek telescopic attachments for two implants retained mandibular complete overdentures :
المؤلف
El-Bashir, Samah Al-Fadul El-Hag.
هيئة الاعداد
باحث / سماح الفضل الحاج البشير
مشرف / رضوي محسن كمال عميرة
مشرف / جيلان يوسف عبدالحليم الطنباري
مناقش / جيلان يوسف عبدالحليم الطنباري
الموضوع
PEEK. Zicronia. Telescopic Attachments.
تاريخ النشر
2018.
عدد الصفحات
141 P. :
اللغة
الإنجليزية
الدرجة
ماجستير
التخصص
Periodontics
تاريخ الإجازة
01/12/2019
مكان الإجازة
جامعة المنصورة - كلية طب الأسنان - Department of Removable Prosthodontic
الفهرس
Only 14 pages are availabe for public view

from 141

from 141

Abstract

Purpose: This in-vitro study was performed to evaluate and compere stresses applied to the implants retaining mandibular complete overdenture with three different resilient telescopic attachments.Materials and methods: Three identical clear acrylic resin models of completely edentulous mandibular arch were selected for this study. One implant was installed in each canine region of the models by using guide template. The models were scanned to design telescopic attachment using CAD/CAM technology on model 3D virtual image. According to the material of fabrication of the resilient telescopic attachment, the models were categorized as follows: (All Zirconia telescopic group ZZ): The primary and secondary telescopic crowns were made from ZrO2. (All Peek telescopic group PP): The primary and secondary were made from PEEK. (Zirconia Peek telescopic group PP): The primary was made from ZrO2 and secondary telescopic was made from PEEK. Three identical mndibular complete overdentures were constructed. The secondary telescopic crowns of each group were picked up within the intaglio surface of each overdenture. Four strain gauges were installed on the buccal, lingual, mesial and distal side parallel for each implant. A unilateral and bilateral load of 70N was applied. The loading protocol was repeated five times for each loading application.Results: In bilateral loading the highest stresses were recorded with PP, followed by ZZ and the lowest stresses were noted with ZP for mesial and buccal sites, while in unilateral loading The highest stresses were recorded with PP, followed by ZZ and the lowest stresses was noted with ZP for all sites.Conclusion: Within limitation of this in vitro study it could be concluded that:Telescopic attachments that fabricated from Zirconia primary crown and Peek secondary crown is a promising attachment regarding reductions of stresses transmitted to the implants retaining mandibular complete overdendure.