Search In this Thesis
   Search In this Thesis  
العنوان
Evaluation of biocompatibility of bio HPP crown veneered with visio-lign compared to lithium disilicate (e.max) crown veneered with e.max veneering system in anterior aesthetic zone :
الناشر
Esra{u2019}a Mohamed Ali Mraweh Odeh ,
المؤلف
Esra{u2019}a Mohamed Ali Mraweh Odeh
هيئة الاعداد
باحث / Esra’a Mohamed Ali Mraweh Odeh
مشرف / Hesham Alansary
مشرف / Ahmed Nagiub
مشرف / Maha Ahmad Taymour
مناقش / Rana Mahmoud Sherif
تاريخ النشر
2020
عدد الصفحات
179 P. :
اللغة
الإنجليزية
الدرجة
الدكتوراه
التخصص
Dentistry (miscellaneous)
تاريخ الإجازة
8/2/2020
مكان الإجازة
جامعة القاهرة - الفم والأسنان - Fixed Prosthodontics
الفهرس
Only 14 pages are availabe for public view

from 201

from 201

Abstract

Aim:To evaluate biocompatibility and bacteria count and typeof Bio HPP crowns veneered with visio-lign versus e.max crowns veneered with e.mx veneering system.Methodology:Forty-two full coverage crowns were fabricated for maxillaryanterior teeth. Scaling and polishing was performed for all the patients one week prior to preparation. Pocket depth was measured using William Periodontal probe and swap from the margins and sulcus was obtained using sterile paper cone.These measurements were repeated after three, six, nine and twelve months respectively. The patients were divided into two groups according to the materialgroup 1(control group) fabricated from IPS e.max crowns and Group2(intervention group) fabricated from Bio HPP crowns. The preparation was standardized with equi-gingival, chamfer finish line for all teeth.The try-in and provisionization was performed using Cad\Cam (CAM5-S1) machinewith software (Exocad). Fabrication of the crowns was performed using lost wax press technique. The restorations were veneered according to manufactures instructions.The restoration surfaces were treated according to the manufacture instruction of each material. Self-adhesive cement (by BISCO) was used for both groups.Biocompatibility (bleeding on brushing) was also evaluated during each recall visit using questionnaireto determine patientsatisfaction Results: ANOVA was used to compare between the twogroups. ; there was no statistically significant difference between mean PD at the two materials{u2019} sides except after 9 as well as 12 months; BioHPP showed statistically significantly higher mean PD than e.max. Fisher{u2019}s exact test showed there was no statistically significant difference between total bacterial counts of the two materials. No statistically significant difference between both groups regarding patient satisfaction (bleeding on brushing)