Search In this Thesis
   Search In this Thesis  
العنوان
Assessement of low speed drilling without irrigation versus conventionnel drilling with irrigation regarding heat generation and peri-implant marginal bone loss :
الناشر
Mahmoud Abdelsattar Abdelmotagaly ,
المؤلف
Mahmoud Abdelsattar Abdelmotagaly
هيئة الاعداد
باحث / Mahmoud Abdel Sattar Abdel Motagaly
مشرف / AmrHosny El Khadem
مشرف / Mohamed Atef Abdel Rassoul
مناقش / Hesham Fattouh Abdallah Ramadan
تاريخ النشر
2020
عدد الصفحات
121 P. :
اللغة
الإنجليزية
الدرجة
ماجستير
التخصص
Oral Surgery
تاريخ الإجازة
3/7/2020
مكان الإجازة
جامعة القاهرة - الفم والأسنان - Oral Implantology
الفهرس
Only 14 pages are availabe for public view

from 151

from 151

Abstract

Aim of the study: was the assessment of heat generation, marginal bone loss and implant stability after 6 months follow up placed by drilling speed 150 rpm without irrigation compared with implants placed by drilling speed 1200 rpm with irrigation. Methodology : 20 implants were placed in posterior mandible for each groups, the temperature of bone was measured before and after the implant site preparation by thermocouples.The implant stability and the marginal bone loss were evaluated by Ostel device and CBCT respectively. Result: the heat generation was statically difference between the two groups. The implant stability and the marginal bone loss were no statically difference. Conclusion: the low speed drilling 150 rpm without irrigation is a successful and applicable drilling technique in implant site preparation regardless of its relatively high temperature, as it did not exceed the critical limit