Search In this Thesis
   Search In this Thesis  
العنوان
Evaluation of accuracy in computer guided versus free hand immediate implant placement in fresh extraction sockets :
الناشر
Doaa Mohammed Ayman Abdullah Awf ,
المؤلف
Doaa Mohammed Ayman Abdullah Awf
هيئة الاعداد
باحث / Doaa Mohammed Ayman Abdullah Awf
مشرف / Maha Wagdy Elkerdawy
مشرف / Amr Hosny Elkhadem
مناقش / Amal Kaddah
مناقش / Gehan Fekry
تاريخ النشر
2019
عدد الصفحات
144 P . :
اللغة
الإنجليزية
الدرجة
الدكتوراه
التخصص
Dentistry (miscellaneous)
تاريخ الإجازة
9/11/2019
مكان الإجازة
جامعة القاهرة - الفم والأسنان - Prosthodontics
الفهرس
Only 14 pages are availabe for public view

from 165

from 165

Abstract

Aims: The aim of this study was to compare between computer guided and free hand immediate implant placement in fresh extraction sockets in terms of accuracy of implant positioning. Methodology: This is a randomized controlled clinical study with two arm parallel groups with allocation ratio 1:1, which used CBCT imaging and flapless surgical technique to place implants in fresh extraction sockets and compare the accuracy of implant placement when using computer aided surgical guides and free hand techniques. Accuracy measurements were done using Blusky®1software. A total of 22 patients were diagnosed and selected according to inclusion and exclusion criteria. Each patient received implants was restored at the end of the study with a fixed prosthesis