Retention and Wear Evaluation of Rigid Telescopic and Nova Loc Attachments for Two Implant-Supported Mandibular Overdentures :
المؤلف
Rana Mohamed Abdelhamed Shehata
هيئة الاعداد
باحث / Rana Mohamed Abd El-Hamed Shehata
مشرف / Nora Mohamed Abd El-Badea Cheta
مشرف / Doaa Mahmoud Abd El-Hamid El-kady
مشرف / Hesham Samy Borg
الموضوع
Oral Medicine
تاريخ النشر
2022.
عدد الصفحات
162 p. :
اللغة
الإنجليزية
الدرجة
ماجستير
التخصص
Periodontics
تاريخ الإجازة
1/1/2021
مكان الإجازة
جامعة القاهرة - الفم والأسنان - prosthodontics
الفهرس
Only 14 pages are availabe for public view

from 162

from 162

Abstract

This invitro study was conducted to compare between retention force and wear resistance of telescopic and nova loc dental attachments for two implant – supported mandibular over dentures. An epoxy resin model representing a completely edentulous mandible with a class I (ACP)
The epoxy resin model was prepared with two implants analog in the canine area. Two attachments were ready to be picked up in the denture. In order, telescopic attachment was constructed and picked up in the denture, then nova loc picked up in the other one. the telescopic abutment with 5,5 mm length was used, another abutment made of titanium, and is coated with an amorphous diamond-like carbon was used for nova loc attachment
The two outcomes retention and wear were measured and evaluated at base line and after {500- 1000- 1500 and 2000} cycles corresponding to 3- 6-9 and 12 months of simulated clinical use. The force was applied by using universal testing machine and the surface areas, perimeter and diameter of wear was detected by digital microscope. A denture was placed on the model with 3 hooks, one in the midline of the anterior area of the denture, and the last 2 hooks in the posterior molar area. The force on the denture were applied through the hooks, and then the area of wear detected.
Every attachment was subjected to vertical forces at geographic center of the overdenture {vertical anterior force, vertical posterior} then the retention value and wear resistance was calculated and the results were analyzed
The study revealed that there was statistically significantly reduce in retention in both groups. The initial retention of telescope is much higher than the nova loc, this was one of the causes that explain why the nova loc was lesser than the telescopic one, and this is due to the peek material of cap that also improve its wear resistance