Search In this Thesis
   Search In this Thesis  
العنوان
Evaluation Of The Effect Of Diode Laser Treatment On The Topography And Hydrophilicity Of Titanium Dental Implant Surface (In Vitro Study) /
المؤلف
Rezeka, Mostafa Ahmed Ali taha,
هيئة الاعداد
باحث / مصطفى احمد رزيق
مشرف / محمد معتز خميس
مشرف / سمير عمر سليمان
مشرف / سيد نوار
تاريخ النشر
2024.
عدد الصفحات
59p+2. :
اللغة
الإنجليزية
الدرجة
ماجستير
التخصص
طب الأسنان
تاريخ الإجازة
28/4/2021
مكان الإجازة
جامعة الاسكندريه - كلية طب الاسنان - Department of Prosthodontics
الفهرس
Only 14 pages are availabe for public view

from 59

from 59

Abstract

Attempts have been made to decontaminate the implant surface by using diode lasers. However, the parameters that provide efficient decontamination without altering the topography or surface characteristics of titanium implants are still unclear. The aim of the present study was to evaluate the effect of altering the power of diode laser (940 nm) application on the hydrophilicity, surface topography, and chemical composition of sandblasted, large grit, acid-etched (SLA) treated titanium alloy implant surface.
Materials and methods. Thirty-six SLA-treated titanium discs (Dentis Co., Ltd.) were used in this study. The hydrophilicity of all discs was measured by using a contact angle goniometer (190 CA; Rame-hart Co, Ltd). Discs were randomly divided into four groups (n = 9 each) based on the power of the diode laser used. group I (control, no lasing group), group II: treated with 1 W power, group III: 2 W power, and group IV: 3 W power. The chemical composition of the SLA discs was evaluated by using energy dispersive x-ray spectroscopy (EDX) before laser application. Hydrophilicity was reevaluated after the application of laser irradiation. The surface topography of all discs was examined. Changes in the chemical composition of the titanium discs were investigated following the lasing procedure. Morphometric analysis of the surface area (μm2) of the indentations created following laser application was also evaluated. Data were collected and the Shapiro-Wilk test of normality was used. Comparisons between the four study groups were done by using the Kruskal-Wallis test, while that to evaluate the morphometric analysis of the surface area was done by using One-way ANOVA (P < 0.05).
Results. The average contact angle of the DROP of distilled water to the SLA discs significantly decreased after laser treatment (P < 0.05). The largest contact angle was measured in the control group, followed by the 1 W group, and the 2 W group. The smallest angle was measured in the 3 W group. Considerable surface
11
alterations such as melting and flattening were observed on examination of the surface topography of the 3 W group followed by the 2 W group. The least changes were observed in association with the 1 W group in comparison to the control group. The EDX analysis showed the appearance of peaks of the oxygen and carbon elements after the lasing procedure with the highest percentage in the 3 W group. The average of the surface area of the created indentations significantly increased with increasing the power of the diode laser used (P < 0.05).
Conclusions. The application of diode laser (940 nm) with 2 W and 3 W powers significantly altered the hydrophilicity, the surface topography, and the chemical composition of titanium discs. Diode laser (940 nm) with 1 W power can be safely used on SLA titanium implant surfaces with no damaging effect on the surface topography or hydrophilicity.