The effect of curing cycles on retenetion of upper complete heat cured acrylic denture base /
المؤلف
El Tahan, Ali El sayed.
هيئة الاعداد
باحث / Ali El Sayed El Tahan
مشرف / Omar hassan khashaba
مشرف / Adel ahmed kamar
مشرف / Ibrahim mohamed Elewa
الموضوع
Overlay dentures. Partial dentures. Acrylic acid. Complete dentures.
تاريخ النشر
1988.
عدد الصفحات
87 p. :
اللغة
الإنجليزية
الدرجة
ماجستير
التخصص
طب الأسنان
تاريخ الإجازة
1/1/1988
مكان الإجازة
جامعة المنصورة - كلية طب الأسنان - Prosthodontics
الفهرس
Only 14 pages are availabe for public view

from 113

from 113

Abstract

The present study has been carried out upon twenty—five edentulous patients in Prothodontics Department, Faculty of Dentistry, El—Mansoura University. The purpose of this study was to compare the intraoral retention between two upper complete heat cured acrylic denture bases cured by two different curing cycles.
The two curing cycles used were
i — Short, high temperature curing cycle
Heating the material in water bath at 65°C for 1.5 hours and then at 100°C for -&ne hour.
ii— Long, low temperature curing cycle Heating the material in water bath at 74°C for 9 hours.
The retention of each upper denture base was measured using the retention measuring system consisting of especi ally constructed retention testing rig, two strain gauges, strain indicator unit and X-Y chart recorder unit.
The results of this study revealed that i — There was no statistically significant difference between the two curing cycles on retention of the denture base (the calculated-t Cc) was 1.54 while the tabulated-t Ct) was 2.00 at $ 0.05.